|
|
||||||||||||||
|
|
|||||||||||||||
ORIGINAL ARTICLE |
1 Emergency Department, King's College Hospital, London, UK
2 Department of Accident and Emergency, John Radcliffe Hospital, Oxford
Correspondence to:
Correspondence to:
Dr P Hormbrey, Emergency Department, John Radcliffe Hospital, Oxford OX3 9DU, UK;
phil.hormbrey{at}orh.nhs.uk
Objectives: To determine the normal range for carbon monoxide concentrations in the exhaled breath of subjects in the emergency department and to develop a protocol for the use of a breath analyser to detect abnormal carbon monoxide exposure.
Methods: A hand held breath analyser was used to measure end expiratory carbon monoxide concentrations in 382 consenting subjects. Questionnaire data were collected to assess the effect of common sources of carbon monoxide exposure on breath carbon monoxide levels. Smokers were used as a carbon monoxide exposed group for comparison with non-smokers.
Results: The range of carbon monoxide concentrations obtained in the non-smoking group was 06 ppm and in the smoking group was 168 ppm. Smokers had a mean breath carbon monoxide concentration of 16.4 ppm and non-smokers had a mean of 1.26 ppm (95% confidence interval (CI) for difference 13.6 to 16.8 ppm). Male sex and frequent motor vehicle use were associated with slightly higher carbon monoxide concentrations (by 0.40, 95% CI 0.18 to 0.63 ppm, and 0.38, 95% CI 0.13 to 0.63 ppm, respectively) in the non-smoking group. Mean breath carbon monoxide concentrations increased in direct proportion to the number of cigarettes smoked (p<0.001) and there was a negative correlation between carbon monoxide and time since last smoking a cigarette (p<0.001). Altogether 23% of smokers had breath carbon monoxide concentrations in the range 16 ppm.
Conclusions: Breath analysis was rapid and results correlated well with carbon monoxide exposure. In this population subjects with breath carbon monoxide concentrations greater than 6 ppm should be assessed for the risk of carbon monoxide poisoning. However even carbon monoxide concentrations less than 6 ppm do not exclude carbon monoxide poisoning within the last 24 hours.
Keywords: breath analysis; carbon monoxide; diagnosis; poisoning
Abbreviations: COHb; carboxyhaemoglobin; CI, confidence interval
This article has been cited by other articles:
![]() |
N. Alia-Klein, R. Z. Goldstein, A. Kriplani, J. Logan, D. Tomasi, B. Williams, F. Telang, E. Shumay, A. Biegon, I. W. Craig, et al. Brain Monoamine Oxidase A Activity Predicts Trait Aggression J. Neurosci., May 7, 2008; 28(19): 5099 - 5104. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. S. Pearce, L. Hayes, and on behalf of the Newcastle Heart Project and the N Self-Reported Smoking Status and Exhaled Carbon Monoxide: Results From Two Population-Based Epidemiologic Studies in the North of England Chest, September 1, 2005; 128(3): 1233 - 1238. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. Zetterquist, J.O.N. Lundberg, and K. Alving From the Authors Eur. Respir. J., January 1, 2003; 21(1): 197 - 198. [Full Text] [PDF] |
||||
![]() |
I Horvath, S Loukides, T Wodehouse, E Csiszer, P J Cole, S A Kharitonov, and P J Barnes Comparison of exhaled and nasal nitric oxide and exhaled carbon monoxide levels in bronchiectatic patients with and without primary ciliary dyskinesia Thorax, January 1, 2003; 58(1): 68 - 72. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS | REGISTER |